DENARE WATERPROOFING TECHNOLOGIES AUSTRALIA
COATINGS & SPORTS SURFACES
WATER-STOP
EXTERIOR FINISH

Weather
resistant liquid membrane used for long term waterproofing and decoration
of building surfaces.
DESCRIPTION:
WATER-STOP EXTERIOR FINISH
forms a flexible waterproof lining that is resistant to weathering
for many years. Although the membrane is waterproof it allows substrate
moisture to breathe reducing the possibility of blistering. WATER-STOP
EXTERIOR FINISH
may be applied to slightly damp walls. it is UV stable, fungal and algae resistant
and is easily maintained.
USES:
- Trafficable concrete roof deck membrane.
- Balconies with or without tiling.
- Concrete or block work walls, parapets and plywood decks.
- Asbestos roof encapsulation.
- Metal roofs, wall gutters. Facias-new and old.
- Concrete silos and plant room floors.
PREPARATION:
- All surfaces shall be sound, clean, dry and free of release
oils and other contaminates. Check by applying a test area.
Sound painted surfaces are usually suitable after removing chalk.
Roof decks should be properly drained for long term serviceability
of WATER-STOP EXTERIOR FINISH.
Ponding areas deeper than 8mm should be filled and levelled. Apply a 10mm bead
of Denare polyurethane sealant as a bond breaker at corner
details and other penetrations.
- Concrete: remove any laitance or soft concrete by
acid etch or water blast. Prime horizontal surfaces with Denare
Primer/ Sealer applied at 8-6m²/litre. Apply a detail coat of
WATER-STOP EXTERIOR FINISH
to fine cracks. Cracks over 1mm to be cut out and filled with Denare
polyurethane sealant, then covered with a 100mm wide strip of
reinforced WATER-STOP EXTERIOR FINISH.
-
Particle Board and Plywood: Apply a detail coat of reinforced WATER-STOP
EXTERIOR FINISH
to all joints filled with Denare polyurethane sealant. Fill fastening points.
Only reinforce WATER-STOP EXTERIOR FINISH
over joins and penetrations on AC sheeting.
- Compressed Fibrous Cement: prime with Denare
Hydrepoxy. Apply WATER-STOP EXTERIOR FINISH
with reinforcement to all joints and cracks with Denare polyurethane
sealant. Seal and fill fastening points.
- Galvanize/Zincalume: WATER-STOP EXTERIOR FINISH
may be applied to new surfaces after degreasing. Prime heavily oxidised surfaces.
Prime rusted surfaces or where exposed to a corrosive environment
with Denare metal primer.
- Aged Water-Stop Exterior Finish: High pressure wash to remove
chalk etc. prime with Denare primer/sealer then apply WATER-STOP
EXTERIOR FINISH
to specified thickness.
APPLICATION:
- WATER-STOP EXTERIOR FINISH
may be applied by brush, roller or spray.
- Vertical surfaces should receive two coats each of 3m²/L
for normal waterproofing.
- Horizontal surfaces, such as roof decks should receive a
minimum of 3 coats with reinforcement if necessary. Reinforce
WATER-STOP EXTERIOR FINISH
with Denare scrim over cracks, joins and movement areas and 125gsm fibreglass
elsewhere. Place the reinforcing fabric onto the wet surface
of the first coat then apply a further coat and work in carefully
by brush or roller to fully saturate the fibreglass. Apply a
further two or more coats. Approximately 1.4lts of WATER-STOP
EXTERIOR FINISH
is needed per square metre.
TECHNICAL DATA:
| Shelf Life: |
2 years
in sealed containers stored 20°C |
| Colour: |
Grey, White
& Colours to order |
| Elongation
at break: |
160% approx. |
| Density: |
1.25kg/litre |
| Moisture
Vapour Transfer: |
0.45g/h-m² |
| Touch dry: |
1 hour
depending on thickness |
| Recoat
time: |
Any time
after firm and dry |
| Application
temperature: |
Minimum
8°C, Maximum 35°C |
| Coverage: |
1m²/litre/0.5mm
dry film |
PRECAUTIONS: Areas
subject to rising damp should be first sealed with Denare
Hydrepoxy 300. Protect membrane from traffic prior and during tiling.
Do not allow solvents to contact WATER-STOP EXTERIOR FINISH.
CLEAN
UP: Uncured WATER-STOP products
may be removed with water.
Statements made in this bulletin are for the assistance of our customers. They are based on
our experience and judgement but must not be regarded as amounting to a legal warranty or as involving any liability
on our part
Back to Coatings & Sports Surfaces index

   


|